BibTex format
@article{Ho:1998:10.1049/el:19981607,
author = {Ho, YKE and Hui, SYR and Lee, YS},
doi = {10.1049/el:19981607},
journal = {Electronics Letters},
pages = {2300--2301},
title = {Optimal operation of single-stage three-phase power factor correction circuit using modular PWM DC-to-DC converters},
url = {http://dx.doi.org/10.1049/el:19981607},
volume = {34},
year = {1998}
}
RIS format (EndNote, RefMan)
TY - JOUR
AB - A critical conduction parameter A3Φ is derived for the three-phase modular system. This parameter optimises the output filter to achieve the highest power factor of the system. The voltage conversion ratio required to achieve a high power factor to fulfil the harmonic requirements is also derived. Both simulations and experimental results from a 1.5kW prototype using full-bridge converters have confirmed the analysis.
AU - Ho,YKE
AU - Hui,SYR
AU - Lee,YS
DO - 10.1049/el:19981607
EP - 2301
PY - 1998///
SN - 0013-5194
SP - 2300
TI - Optimal operation of single-stage three-phase power factor correction circuit using modular PWM DC-to-DC converters
T2 - Electronics Letters
UR - http://dx.doi.org/10.1049/el:19981607
VL - 34
ER -