Citation

BibTex format

@article{Akerib:2025:10.1103/PhysRevLett.134.061002,
author = {Akerib, DS and Alsum, S and Araújo, HM and Bai, X and Balajthy, J and Bang, J and Baxter, A and Bernard, EP and Bernstein, A and Biesiadzinski, TP and Boulton, EM and Boxer, B and Brás, P and Burdin, S and Byram, D and Carmona-Benitez, MC and Chan, C and Cutter, JE and de, Viveiros L and Druszkiewicz, E and Fan, A and Fiorucci, S and Gaitskell, RJ and Ghag, C and Gilchriese, MGD and Gwilliam, C and Hall, CR and Haselschwardt, SJ and Hertel, SA and Hogan, DP and Horn, M and Huang, DQ and Ignarra, CM and Jacobsen, RG and Jahangir, O and Ji, W and Kamdin, K and Kazkaz, K and Khaitan, D and Korolkova, EV and Kravitz, S and Kudryavtsev, VA and Leason, E and Lesko, KT and Liao, J and Lin, J and Lindote, A and Lopes, MI and Manalaysay, A and Mannino, RL and Marangou, N and McKinsey, DN and Mei, D-M and Morad, JA and Murphy, ASJ and Naylor, A and Nehrkorn, C and Nelson, HN and Neves, F and Nilima, A and Oliver-Mallory, KC and Palladino, KJ and Rhyne, C and Riffard, Q and Rischbieter, GRC and R},
doi = {10.1103/PhysRevLett.134.061002},
journal = {Phys Rev Lett},
title = {Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity.},
url = {http://dx.doi.org/10.1103/PhysRevLett.134.061002},
volume = {134},
year = {2025}
}

RIS format (EndNote, RefMan)

TY  - JOUR
AB - Dual-phase xenon time projection chamber (TPC) detectors offer heightened sensitivities for dark matter detection across a spectrum of particle masses. To broaden their capability to low-mass dark matter interactions, we investigated the light and charge responses of liquid xenon (LXe) to sub-keV nuclear recoils. Using neutron events from a pulsed Adelphi Deuterium-Deuterium neutron generator, an in situ calibration was conducted on the LUX detector. We demonstrate direct measurements of light and charge yields down to 0.45 and 0.27 keV, respectively, both approaching single quanta production, the physical limit of LXe detectors. These results hold significant implications for the future of dual-phase xenon TPCs in detecting low-mass dark matter via nuclear recoils.
AU - Akerib,DS
AU - Alsum,S
AU - Araújo,HM
AU - Bai,X
AU - Balajthy,J
AU - Bang,J
AU - Baxter,A
AU - Bernard,EP
AU - Bernstein,A
AU - Biesiadzinski,TP
AU - Boulton,EM
AU - Boxer,B
AU - Brás,P
AU - Burdin,S
AU - Byram,D
AU - Carmona-Benitez,MC
AU - Chan,C
AU - Cutter,JE
AU - de,Viveiros L
AU - Druszkiewicz,E
AU - Fan,A
AU - Fiorucci,S
AU - Gaitskell,RJ
AU - Ghag,C
AU - Gilchriese,MGD
AU - Gwilliam,C
AU - Hall,CR
AU - Haselschwardt,SJ
AU - Hertel,SA
AU - Hogan,DP
AU - Horn,M
AU - Huang,DQ
AU - Ignarra,CM
AU - Jacobsen,RG
AU - Jahangir,O
AU - Ji,W
AU - Kamdin,K
AU - Kazkaz,K
AU - Khaitan,D
AU - Korolkova,EV
AU - Kravitz,S
AU - Kudryavtsev,VA
AU - Leason,E
AU - Lesko,KT
AU - Liao,J
AU - Lin,J
AU - Lindote,A
AU - Lopes,MI
AU - Manalaysay,A
AU - Mannino,RL
AU - Marangou,N
AU - McKinsey,DN
AU - Mei,D-M
AU - Morad,JA
AU - Murphy,ASJ
AU - Naylor,A
AU - Nehrkorn,C
AU - Nelson,HN
AU - Neves,F
AU - Nilima,A
AU - Oliver-Mallory,KC
AU - Palladino,KJ
AU - Rhyne,C
AU - Riffard,Q
AU - Rischbieter,GRC
AU - Rossiter,P
AU - Shaw,S
AU - Shutt,TA
AU - Silva,C
AU - Solmaz,M
AU - Solovov,VN
AU - Sorensen,P
AU - Sumner,TJ
AU - Swanson,N
AU - Szydagis,M
AU - Taylor,DJ
AU - Taylor,R
AU - Taylor,WC
AU - Tennyson,BP
AU - Terman,PA
AU - Tiedt,DR
AU - To,WH
AU - Tvrznikova,L
AU - Utku,U
AU - Vacheret,A
AU - Vaitkus,A
AU - Velan,V
AU - Webb,RC
AU - White,JT
AU - Whitis,TJ
AU - Witherell,MS
AU - Wolfs,FLH
AU - Woodward,D
AU - Xiang,X
AU - Xu,J
AU - Zhang,C
DO - 10.1103/PhysRevLett.134.061002
PY - 2025///
TI - Nuclear Recoil Calibration at Sub-keV Energies in LUX and Its Impact on Dark Matter Search Sensitivity.
T2 - Phys Rev Lett
UR - http://dx.doi.org/10.1103/PhysRevLett.134.061002
UR - https://www.ncbi.nlm.nih.gov/pubmed/40021173
VL - 134
ER -