Our Hamlyn researchers proposed a distributed force control scheme for micro-robot manipulation, aiming to assist various cell surgery applications.
In cell surgery applications, cells must be oriented properly to enable the microsurgical tool to access the target components with minimum damage to cells. Therefore, orientation control of biological cells is extremely crucial.
In traditional biological applications such as intra-cytoplasmic sperm injection, out-of-plane rotation is generally performed manually by operating two micro-pipettes to repeat vacuum aspiration and release of the mature oocyte until it is oriented at a desired pose.
Optical tweezers (OT) represent a versatile tool for micro-manipulation of micro-robots. To avoid damages to living cells caused by illuminating laser directly on them, micro-robots controlled by OT can be used for manipulation of cells or living organisms in microscopic scale. In addition, translation and planar rotation motion of micro-robots can be realised by using a multi-spot planar OT.
In spite of that, out-of-plane manipulation of micro-robots is difficult to achieve with a planar OT until these days, owing to its complex and costly settings.
A distributed force control scheme for micro-robot manipulation via planar multi-spot optical tweezer
In view of this, our research team at the Hamlyn Centre proposed a distributed force control scheme for micro-robot manipulation via planar multi-spot OT, which can control the out-of-plane pose of a micro-robot along multiple axes.
A general mathematical model is used to construct a series of micro-robots for the implementation of out-of-plane control along multiple axes, which has potential applications for micro-object manipulation.
Two distributed force control strategies are proposed and investigated, namely Control Based on Various Characteristic Distance (Control Strategy A) and Control Based on Various Power Intensity Distribution (Control Strategy B).
Different micro-robot designs are investigated and fabricated for experimental validation. The structure design of the micro-robot and the investigation of two control strategies enable the control of out-of-plan rotation of optical micro-robots via planar OT.
The control input is the range of planar motions or power intensity distribution of the laser spots while the output is the multi-dimensional (6D) pose of the micro-robot.
Our researchers pointed out that such optically driven micro-robots can be used for complex manipulation in a closed environment, such as a micro-fluidic chip. It can also assist cell surgery by providing dexterous manipulation.
Moreover, the proposed scheme can be potentially applied to various cell surgery applications, including single-cell analysis, embryo injection, nucleus transplantation, organelle biopsy in precision medicine, bottom-up cell assembly for tissue engineering, or other assembly tasks.
Overall, the main contributions of this research can be concluded as follows:
- Development of a generic model for the structure design of micro-robots which enables multi-dimensional (6D) control via conventional multi-spot OT.
- Introduction of two distributed force control strategies for micro-robot manipulation based on characteristic distance and power intensity distribution.
- Experiments are performed to demonstrate the effectiveness of the proposed method and the potential applications that this model can be applied to (including indirect manipulation of micro-objects).
- The structure design and the control strategies are both applicable to HOT (holographic optical tweezer) or other types of conventional OT systems, where the focal points of optical traps are limited to the focal plane. It goes without saying that, adding more degrees of freedom by using the micro-robot design is the first step toward fibre-based optical trap compatible micro-robot.
- Such micro-robots can be used as a tool at the tip of a fibre to manipulate micro-objects or implement tissue biopsy using the optical traps generated by multiple optical fibres. In addition, it can be used as a dexterous tool for lab-on-the-chip to realise cell diagnosis.
This research was supported by EPSRC Programme Grant “Micro-robotics for Surgery (EP/P012779/1)” ( , "Distributed Force Control for Microrobot Manipulation via Planar Multi-Spot Optical Tweezer", Advanced Optical Materials, August 2020, 2000543).