BibTex format
@article{Strucka:2022:10.1063/5.0059926,
author = {Strucka, J and Halliday, JWD and Gheorghiu, T and Horton, H and Krawczyk, B and Moloney, P and Parker, S and Rowland, G and Schwartz, N and Stanislaus, S and Theocharous, S and Wilson, C and Zhao, Z and Shelkovenko, TA and Pikuz, SA and Bland, SN},
doi = {10.1063/5.0059926},
journal = {Matter and Radiation at Extremes},
pages = {1--11},
title = {A portable X-pinch design for x-ray diagnostics of warm dense matter},
url = {http://dx.doi.org/10.1063/5.0059926},
volume = {7},
year = {2022}
}
RIS format (EndNote, RefMan)
TY - JOUR
AB - We describe the design and x-ray emission properties (temporal, spatial, and spectral) of Dry Pinch I, a portable X-pinch driver developed at Imperial College London. Dry Pinch I is a direct capacitor discharge device, 300 × 300 × 700 mm3 in size and ∼50 kg in mass, that can be used as an external driver for x-ray diagnostics in high-energy-density physics experiments. Among key findings, the device is shown to reliably produce 1.1 ± 0.3 ns long x-ray bursts that couple ∼50 mJ of energy into photon energies from 1 to 10 keV. The average shot-to-shot jitter of these bursts is found to be 10 ± 4.6 ns using a combination of x-ray and current diagnostics. The spatial extent of the x-ray hot spot from which the radiation emanates agrees with previously published results for X-pinches—suggesting a spot size of 10 ± 6 µm in the soft energy region (1–10 keV) and 190 ± 100 µm in the hard energy region (>10 keV). These characteristics mean that Dry Pinch I is ideally suited for use as a probe in experiments driven in the laboratory or at external facilities when more conventional sources of probing radiation are not available. At the same time, this is also the first detailed investigation of an X-pinch operating reliably at current rise rates of less than 1 kA/ns.
AU - Strucka,J
AU - Halliday,JWD
AU - Gheorghiu,T
AU - Horton,H
AU - Krawczyk,B
AU - Moloney,P
AU - Parker,S
AU - Rowland,G
AU - Schwartz,N
AU - Stanislaus,S
AU - Theocharous,S
AU - Wilson,C
AU - Zhao,Z
AU - Shelkovenko,TA
AU - Pikuz,SA
AU - Bland,SN
DO - 10.1063/5.0059926
EP - 11
PY - 2022///
SN - 2468-080X
SP - 1
TI - A portable X-pinch design for x-ray diagnostics of warm dense matter
T2 - Matter and Radiation at Extremes
UR - http://dx.doi.org/10.1063/5.0059926
UR - http://gateway.webofknowledge.com/gateway/Gateway.cgi?GWVersion=2&SrcApp=PARTNER_APP&SrcAuth=LinksAMR&KeyUT=WOS:000719738500001&DestLinkType=FullRecord&DestApp=ALL_WOS&UsrCustomerID=1ba7043ffcc86c417c072aa74d649202
UR - https://aip.scitation.org/doi/10.1063/5.0059926
UR - http://hdl.handle.net/10044/1/94445
VL - 7
ER -