The MIM Lab develops robotic and mechatronics surgical systems for a variety of procedures.

Head of Group

Prof Ferdinando Rodriguez y Baena

B415C Bessemer Building
South Kensington Campus

+44 (0)20 7594 7046

⇒ X: @fmryb

 

What we do

The Mechatronics in Medicine Laboratory develops robotic and mechatronics surgical systems for a variety of procedures including neuro, cardiovascular, orthopaedic surgeries, and colonoscopies. Examples include bio-inspired catheters that can navigate along complex paths within the brain (such as EDEN2020), soft robots to explore endoluminal anatomies (such as the colon), and virtual reality solutions to support surgeons during knee replacement surgeries.

Meet the team

No results found

Search or filter publications

Filter by type:

Filter by publication type

Filter by year:

to

Results

  • Showing results for:
  • Reset all filters

Search results

  • Journal article
    Frasson L, Ferroni F, Ko S, Dogangil G, Rodriguez y Baena Fet al., 2012,

    Experimental evaluation of a novel steerable probe with a programmable bevel tip inspired by nature

    , Pages: 1-9, ISSN: 1863-2483
  • Conference paper
    Oldfield M, Dini D, Rodriguez y Baena F, 2012,

    Predicting Failure in Soft Tissue Phantoms via Modeling of Non-Predetermined Tear Progression

    , 34th Annual International Conference of the IEEE Engineering-in-Medicine-and-Biology-Society (EMBS), Publisher: IEEE, Pages: 6305-6308, ISSN: 1557-170X
  • Conference paper
    Bano S, Ko SY, Rodriguez y Baena F, 2012,

    Smooth Path Planning for a Biologically-Inspired Neurosurgical Probe

    , 34th Annual International Conference of the IEEE Engineering-in-Medicine-and-Biology-Society (EMBS), Publisher: IEEE, Pages: 920-923, ISSN: 1557-170X
  • Conference paper
    Caborni C, Ko SY, De Momi E, Ferrigno G, Rodriguez y Baena Fet al., 2012,

    Risk-Based Path Planning for a Steerable Flexible Probe for Neurosurgical Intervention

    , 4th IEEE RAS and EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) / Symposium on Surgical Robotics, Publisher: IEEE, Pages: 866-871, ISSN: 2155-1782
  • Journal article
    Oldfield M, Dini D, Giordano G, Rodriguez y Baena Fet al., 2012,

    Detailed finite element modelling of deep needle insertions into a soft tissue phantom using a cohesive approach

    , ISSN: 1476-8259

    Detailed finite element modelling of needle insertions into soft tissue phantoms encounters difficulties of large deformations, high friction, contact loading and material failure. This paper demonstrates the use of cohesive elements in high-resolution finite element models to overcome some of the issues associated with these factors. Experiments are presented enabling extraction of the strain energy release rate during crack formation. Using data from these experiments, cohesive elements are calibrated and then implemented in models for validation of the needle insertion process. Successful modelling enables direct comparison of finite element and experimental force-displacement plots and energy distributions. Regions of crack creation, relaxation, cutting and full penetration are identified. By closing the loop between experiments and detailed finite element modelling, a methodology is established which will enable design modifications of a soft tissue probe that steers through complex mechanical interactions with the surrounding material.

  • Journal article
    Ko SK, Rodriguez y Baena F, 2012,

    Towards a Miniaturized Needle Steering System with Path Planning for Obstacle Avoidance

    , IEEE Transactions on Biomedical Engineering, Vol: N/A
  • Journal article
    Parittotokkaporn T, Thomas DG, Schneider A, Huq E, Davies BL, Degenaar P, Rodriguez y Baena Fet al., 2011,

    Microtextured Surfaces for Deep-Brain Stimulation Electrodes: A Biologically Inspired Design to Reduce Lead Migration

    , World Neurosurgery, Vol: 77, Pages: 569-576, ISSN: 1878-8750

    OBJECTIVE: Hardware-related complications of deep brain stimulation (DBS) surgery have been reported with adverse effects in postoperative electrode migration. We report that the addition of microtextured features to the surface of a DBS-like probe can minimize the extent of electrode migration in ex vivo porcine brain. METHODS: A DBS lead and microtextured strips, mounted with a fiberoptic displacement sensor, were embedded 15-mm deep inside a cadaveric porcine brain through holes on the skull. The local displacement of brain tissue surrounding each strip was detected along the direction of insertion by the optical sensor while the porcine head simulated brain shift during rotation between supine and upright postures. RESULTS: The triangular toothed strip with protruding height of 250 mum enabled a better grip of the surrounding brain tissue than standard DBS lead, minimizing local brain displacement to 77 mum versus 326 mum respectively, when the porcine head was shifted from the supine to the upright position as the result of gravity. In addition, brain tissue damage resulting from the removal of toothed strips exhibited less-extensive tissue disruption, attributable to the microtextured surface. CONCLUSIONS: These preliminary results show that microtextured strips embedded into cadaveric porcine brain produce an anchoring effect on local tissue during brain shift, suggesting a way to reduce DBS lead migration without additional tissue damage beyond the strip geometry.

  • Conference paper
    Tenzer Y, Bowyer S, Davies BL, Rodriguez Y Baena Fet al., 2011,

    "Sticking" aspects of a haptic device with part-locking programmable brakes

    , Pages: 269-274

    This paper outlines work on the development of a novel programmable rotary brake which can restrict motion of a mechanism moving in one direction whilst allowing free motion in other directions. The design, implementation and performance of a fully functional prototype are described along the work on incorporating the prototype into a 3 Degrees-Of-Freedom (DOF) haptic device. The ability of the haptic device to constrain the motion of the end-effector to point-constraint was investigated and the experiments have shown that the haptic device can implement virtual constraints without the need for a force sensor. The experiments also show that when an advanced control scheme is used the virtual wall is not felt as "sticky". © 2011 IEEE.

  • Conference paper
    Manoharan V, Tenzer Y, Rodriguez Y Baena F, 2011,

    Experimental evaluation of a 2DOF haptic device with four-state rotary programmable brakes

    , Pages: 125-130

    Safety is an important factor for human-machine interface devices. Brake actuated devices are potentially safer than those that rely on motors for force-feedback generation. However, manipulators using conventional frictional brakes do have limitations. This paper presents the experimental evaluation of a newly developed four-state rotary programmable brake in a 2DOF manipulator. The experimental results show improved performance compared to the results obtained when manipulators with conventional frictional brakes are used. © 2011 IEEE.

  • Journal article
    Tenzer Y, Davies BL, Rodriguez y Baena F, 2011,

    Four-State Rotary Joint Control: Results With a Novel Programmable Brake

    , Mechatronics, IEEE/ASME Transactions on, Vol: 17, Pages: 915-923, ISSN: 1083-4435

This data is extracted from the Web of Science and reproduced under a licence from Thomson Reuters. You may not copy or re-distribute this data in whole or in part without the written consent of the Science business of Thomson Reuters.

Request URL: http://www.imperial.ac.uk:80/respub/WEB-INF/jsp/search-t4-html.jsp Request URI: /respub/WEB-INF/jsp/search-t4-html.jsp Query String: id=1303&limit=10&page=15&respub-action=search.html Current Millis: 1732241552874 Current Time: Fri Nov 22 02:12:32 GMT 2024

Contact Us

General enquiries

Facility enquiries


The Hamlyn Centre
Bessemer Building
South Kensington Campus
Imperial College
London, SW7 2AZ
Map location